Chapter 5: Design of continuous RC beam

Get premium Best Assignment Writing Service Australia with expert-written, well-researched content aligned with Australian university standards. Review our free sample to assess our quality and academic excellence before ordering.

5.1 Introduction

The backbone of any structural system is reinforced concrete (RC) beams, and the so-called load is transferred to the vertical in the case of wall and column. Continuous beam in multi storey buildings is preferable in a building over simply supported beam, on the basis of providing increased structural efficiency, minimisation of deflections and expansion of the control of cracks. The current experiment is associated with the specific project of the design of a continuous T-beam on the 5 th floor in the zone, Zone 04 in particular with Axis 4 alignment and the length of 3.6 m without support. The beam is hyped based on the Australian Standard AS3600-2009, which includes normalisation of limit state principles in both strength and serviceability designs, together with the reinforcement detailing conditions.

The slab panel is loaded with dead loads, live loads and special water pressure loads due to the jacuzzi facility on the beam. The bending moment (M = 89.82 kNm) and shear force (V = 99.92 kN) have been obtained already with the help of the structural analysis. This chapter evolves these values into a step-by-step process of design to include geometry, load considerations, bending/shear design considerations to include serviceability cheques, and detail reinforcements to include detailing of the reinforcement.

5.2 Beam Geometry and Material Properties

5.2.1 Geometrical Parameters

Beam span (L): 3600 mm (centre-to-centre support).

Overall depth (h): 500 mm.

Web (stem) width (bw): 250 mm.

Effective depth (d):

d = h− cover− (bar diameter/2) =500−25−12=463 mm

Effective flange width (bf): Controlled by AS3600 provisions:

bw+2(6hf)=250+2(6×300)=3850 mm

bw+L/4=250+3600/4=1150 mm

Actual flange width = 3600 mm.

Governing limit: bf = 1150 mm.
5.2.2 Material Properties

Concrete grade: N32.

Characteristic compressive strength, f’c=32 MPa

Modulus of elasticity, Ec=30,100 MPa.

Unit weight = 24 kN/m³.
Reinforcement grade: D500N deformed bars.

Concerned About Completing Your Academic Project?
Connect with us for professional support and guidance.

Yield strength, fsy=500 MPa.

Modulus of elasticity, Es=200,000 MPa.

Concrete cover: 25 mm (Exposure class A2).

The beam geometry provides a 3.6 m span on a depth of 500 mm and a web of 250 mm that can provide a useful depth of 463 mm (Selvaraj & Chan, 2024). According to AS3600 the flange width is restricted to 1150 mm. Materials are N32 concrete, fc =32 Mpa and D500N steel reinforcement.

5.3 Load Assessment

5.3.1 Dead Loads (G)

Self-weight of slab (300 mm thick):

24×0.30=7.2 kN/m²

Finishes (ceramic tiles, gypsum ceilings, etc.): range 0.27 – 0.50 kN/m² depending on room type.

Average superimposed load considered = 0.33 kN/m².

5.3.2 Live Loads (Q)

Corridor: 4.0 kN/m² (AS1170.1).

Service room: 2.0 kN/m².

Kids’ room: 4.0 kN/m².

Jacuzzi: 2.0 kN/m² + 12.0 kN/m² water load.

5.3.3 Load Combinations (ULS)

Critical case:

Wu=1.2G+1.5Q

Using G = 7.53 kN/m², Q = 14 kN/m²:

Wu=1.2×7.53+1.5×14=30.04 kN/m²

5.3.4 Load Transfer to Beam

Tributary width = 1.8 m (half span of slab on each side).

Wu,beam=30.04×1.8=54.07 kN/m

Beam self-weight = 1.44 kN/m.

Wu=54.07+1.44=55.51 kN/m

That was calculated by structural analysis to show that the largest bending moment of 89.82 kNm occurs in the beam at ultimate loading. In this respect, the maximum shear force at the supports has the value of 99.92 kN (Hart, D’Amico & Pomponi, 2021). Such values underpins flexural and shear design, which need to fulfil the AS3600 strength and serviceability specifications.

5.4 Beam Design

Design Parameters

Length of beam = 3600 mm

Slab dimension = 3600 x 8000 mm

Concrete grade = N32 (fc = 32 MPa)

Steel grade = D500N (fsy = 500 MPa)

Exposure = A2 class

Concrete cover = 25 mm (AS 3600, table 4.10.3.2)

Laod calculation

Slab thickness = 300 mm

Concrete unit weight = 24 kN/m2

Gslab = 24 x 0.3 = 7.2 kN/m2

Long span = 8000 mm

L/d = 8000/300 = 26.67 ≤ 28 (pass)

Lx = 3600 mm

Ly = 8000 mm

Enjoy Additional Savings on WhatsApp order!
Scan the QR code with your mobile to unlock an exclusive offer! use my discount
scan qr code from mobile

Ly/ Lx = 8000/3600 = 2.22 > 2 (hence ok)

It can be called that spanning is one way (short direction).

Loads Analysis

Service room:

D.L-

Self weight = 7.2 kN/m2

Floor finish = 0.27 kN/m2 (due to ceramic tiles of 10 mm thickness)

Ceiling = 0.13 kN/m2 (gypsum, 13 mm)

Total D.L = 7.60 kN/m2

L.L-

Romm classificatio = A1

Live load (Q) = 2 kN/m2

Kids room:

D.L-

Self weight = 7.2 kN/m2

Floor finish = 0.3 kN/m2 (due to ceramic tiles)

Ceiling = 0.3 kN/m2 (gypsum)

Total D.L = 7.80 kN/m2

L.L-

Romm classificatio = A3

Live load (Q) = 4 kN/m2

Jacuzzi Area:

D.L-

Self weight = 7.2 kN/m2

Floor finish = 0.2 kN/m2 (due to ceramic tiles)

Ceiling = 0.13 kN/m2 (gypsum)

Total D.L (G) = 7.53 kN/m2

L.L-

Romm classification = A2 (toilet area)

Live load (Q) = 2 kN/m2

Water load (Qw) = 12 kN/m2

Total L.L = 14 kN/m2

Beam design parameter

Span = 3600 mm

As per AS3600,

Lh ≤ 10 in case of continuous beam

Hence, min depth, h = 3600/10 = 360 mm

Depth (h) = 500 mm

Width (bw) = 250 mm

Effective depth (d) = 500 – 25 – 12 = 463 mm

T-beam Parameters

Effective width of flange as per AS3600,

bef ≤ bw + 2×(6×hf)

bef ≤ 250 + 2 x (6 x 300)

bef ≤ 3850 mm

or

bef ≤ bw + L/4

bef ≤ 250 + 3600/4

bef ≤ 1150 mm

or

bef ≤ actual flange width

Hence, considering bef = 1150 mm

Load Combinations

G = 7.53 kN/m2

Q = 14 kN/m2

Load combination-

L.C1 = 1.2 G + 1.5 Q

L.C1 = 1.2 x 7.53 + 1.5 x 14

L.C1 = 30.04 kN/m2

L.C2 = 1.35 G

L.C2 = 1.35 x 7.53

L.C2 = 10.17 kN/m2

L.C3 = 0.9 G

L.C3 = 0.9 x 7.53

L.C3 = 6.78 kN/m2

Considering (wu) = L.C1 = 30.04 kN/m2

Beam Loading

Tributary area = 3.6/2 = 1.8 m

UDL on beam (wu,beam) = 30.04 x 1.8

wu,beam = 54.07 kN/m

Additional weight on the beam-

Beam below slab = (0.5 – 0.3) x 0.25 = 0.05 m2

Beam self-weight = 0.05 x 24 = 1.2 kN/m

Ultimate load = 1.2 x 1.2 = 1.44 kN/m

Total ultimate load (wu) = 54.07 + 1.44 = 55.51 kN/m

Structural Analysis

Maximum moment (M) = wu x L2/8

M = 55.51 x 3.62/8

M = 89.82 kNm

Maximum shear (V) = wu x L/2

V = 55.51 x 3.6/2

V = 99.92 kN

Slab ultimate load (wu) = 30.04 kN/m2

Effective span = 3.6 m

Load/width = 30.04 kN/m

Slab max moment (Mslab) = 30.04 x 3.62/8

Mslab = 48.67 kNm

Maximum shear (Vslab) = wu x L/2

V = 30.04 x 3.6/2

V = 54.07 kN

T-beam Section properties

Desihnm moment (M) = 89.82 kNm

Effective depth (d) = 463 mm

Web width (bw) = 250 mm

Effective flange width (bf) = 1150mm

Flange thickness (hf) = 300 mm

fc = 32 MPa

fsy = 500 MPa

Neutral axis check

Ac = bf x hf

Ac = 1150 x 300 = 345000 mm2

Max compressive force (Cc,max) = 0.85 x fc x Ac

Cc,max = 0.85 x 32 x 345000

Cc,max = 9384000 N

In equi;ibrium, T = C

As = M/(0.9 x fsy x d)

As = 89.82/(0.9 x 500 x 463)

As = 430 mm2

Tension force (T) = As × fsy

T = 430 x 500 = 215000 N

T < Cc,max (neutral axis in the flange)

Flexural Design

Neutral axis depth (ku) = √(2 Rn)

Rn = M/( φ × f'c × b × d²)

φ = 0.8

Rn = 89.82 × 106/(0.8 × 32 × 1150 × 4632)

Rn = 0.0129

ku = 0.161

ku,max = 0.4 (AS3600) > ku (tensile failure that is acceptable)

As = (Rn x b x d)/(γ × fsy)

γ = ku(1 - ku/2)

γ = 0.161 (1 – 0.161/2) = 0.148

As = (.0129 x 1150 x 463)/(0.148 x 500)

As = 928 mm2

Steel Requirement

As,min = 0.25√f'c/fsy x b x d

As,min = 0.25√32/500 x 1150 x 463 = 691 mm2

As,max = 0.4 x f'c × b × d/(0.85 × fsy)

As,max = 0.4 x 32 x 1150 x 463/(0.85 x 500) = 40240 mm2

As,min < As < As,max

Providing 4N20 bars

As = 4 x 314 = 1256 mm2

Steel percentage (ρ) = (1256 x 100)/(1150 x 463) = 0.24%

Shear Design

Design shear (V) = 99.92 kN

As,provided = 1256 mm2

Shear capacity (Vuc) = β1  β2 β3 bv dv√f'c

β1 = 1.1 (1.6 - dv/1000)

β1 = 1.1 (1.6 – 463/1000) = 1.09, using 1.1

β2 = 1 (no axial force)

β3 = 1

bv = bw = 250 mm

dv = max of 0.72h or 0.9d

0.72h = 0.72 x 500 = 360

0.9d = 0.9 x 463 = 417

dv = 417 mm

Vuc = 1.1 x 1 x 1 x 250 x 417 x √32 = 637441 = 637.44 kN

Shear Reinforcement

Asv,min/sv ≥ 0.35 35bw/fsy = 0.35 x 250/500 = 0.175 mm2/mm

Providing N10, 2 leg stirrup, Asv = 2 x 78.5 = 157 mm2/mm

Max spacing = 0.5 dv = 0.5 x 417 = 208 mm

Providing N10 stirrup @ 200 mm c/c

Reinforcement Detail

5.5 Structural Analysis

5.5.1 Bending Moment

For a continuous beam approximated as fixed at supports:

M = (Wu L²)/8 = (55.51×3.6²)/ 8 =89.82 kNm

5.5.2 Shear Force

V= (WuL)/2 =55.51×3.62=99.92 kN

5.6 Flexural Design of Beam

5.6.1 Design Bending Strength

The flexural capacity is governed by:

Mu= ϕMn

Where:

ϕ=0.8 (strength reduction factor for flexure).

Mu =89.82 kNm

Therefore, required nominal moment capacity:

Mn=Mu/ϕ =89.82/0.8 =112.28 kNm

5.6.2 Steel Reinforcement Requirement

Lever arm approximation:

z ≈0.9d =0.9×463 =416.7 mm

Required steel area:

Ast =(Mn×106)/(fsy×z) = (112.28×106)/ (500×416.7) ≈539 mm2

5.6.3 Selection of Bars

Provide 2 × N16 bars (area = 402 mm²).

Provide 1 × N12 bar (area = 113 mm²).
Total = 515 mm² (slightly less than 539 mm²).
Using 3 × N16 bars = 603 mm² (satisfies requirement with safety).

 T-beam Reinforcement

5.7 Shear Design

5.7.1 Nominal Shear Stress

τv=Vu/ (bwd) = (99.92×103)/ (250×463) =0.86 MPa

5.7.2 Shear Capacity of Concrete

For N32 grade (AS3600):

Vuc=0.17√f’cbwd =0.17√32×250×463

Vuc=110.2kN

Since Vu=99.92 kN<Vuc, shear reinforcement is not strictly required, but minimum shear reinforcement (stirrups) must be provided as per code.

5.7.3 Shear Reinforcement Provision

Provide 2-legged N10 stirrups at 200 mm spacing across the span.

The flexural design permits the beam to hold safely, the ultimate moment of 89.82 kNm. The characterised strength reduction factor is 0.8; therefore, we need an 112.28 kNm nominal capacity. The area of steel needed is 539 mm2 and the lever arm used is that of 416.7 mm (Kazemi, Asgarkhani & Jankowski, 2023). At first, the demand was slightly higher than 515 mm2 that was given by two N16 bars and one N12 bar. Three N16 bars were taken to be safe as used and provided 603 mm2. Shear analysis indicated 99.92 kN which is less than 110.2 kN of concrete capacity. Nevertheless, according to AS3600, minimum shear reinforcement is obligatory and therefore 2-legged N10 stirrups at 200mm spacing were used (Aghasizadeh, Kari & Fayaz, 2022). This design attains flexural and shear strength requirement to ensure that the beam performs satisfactorily under ultimate loading and that it meets safety and the serviceability consideration.

5.8 Serviceability Checks

5.8.1 Deflection

Span-to-depth ratio check:

L/d=3600/463=7.8<10

Deflection control satisfied.

5.8.2 Crack Width

Beam adequacy under working conditions is checked with serviceability tests. The span/depth ratio is 7.8 which is significantly less than the AS3600 deflection control figure of 10. Adequate reinforcement and 25 mm cover also regulate the width of the crack to satisfy durability and exposure class A2 requirements to long-term performance and safety.

5.9 Reinforcement Detailing

Bottom reinforcement (tension steel): 3 × N16 bars along the span.
Top reinforcement (support regions, negative moments): Provide 2 × N12 bars continuous.
Stirrups: 2-legged N10 @ 200 mm c/c.
Anchorage length: As per AS3600, development length for N16 bars = ~450 mm into supports.

Anchorage length: As per AS3600, development length for N16 bars = ~450 mm into supports.

Reinforcement detailing is one of the most important processes in beam design since calculation is converted into some constructible structures, that are safe and, at the same time, manageable. To take continuous RC T-beam, three N16 bars supply bottom tension precisely during the span so that they form against a positive bending moment. Two constant N12 bars, at the top position, will be used at the locations of support, which contain more negative moments. Shear resistance and ductility is improved by the provision of 2-legged N10 stirrups at the spacing of 200 mm along the beam (Gruyter, 2025). Anchorage is skewed based on AS3600, and an average length of development is about 450 mm on N16 bars that nip into supports. Adequate detailing should be provided in scaled drawings like; beam section, elevation, positioning of beams, and lap lengths to facilitate the right installation on construction.

5.10 Discussion

By the design it is shown that the slab and special hydrostatic applied loads can be safely supported by the continuous RC T-beam. The geometry (500 mm depth, 250 mm width, 1150 mm flange) is low enough in scope to provide sufficient stiffness. The flexural demand (89.82 kNm) corresponds to 3 x N16 bars, which is less than what is needed to provide lift-off shear, nonetheless shear is less than the concrete shear capacity and thus ductility and safety requirements are met through the use of stirrups. Serviceability cheques are used to ensure the deflections and width of the cracks is within reasonable limits.

5.11 Conclusion

The continuous RC beam along Axis 4 has been performed detailing in compliance with the AS3600-2009. Beam can sustain ultimate design loads including extra hydrostatic load of the jacuzzi and reserves safety and strength and serves. The reinforcement scheme that is adopted, 3 x N16 bottom bars, 2 x N12 top bars and N10 stirrups at 200 mm, gives sufficient resistance to flexure and shear and services.

This design excludes only the code but not a well-organised use of materials, which combines economy and safety. The continuous T-beam consequently assures sound workability in the structural system of Zone Z, where it favours the panel held by the slab and connotes sustainability.

Reference List

Journals

  • Arya, C. (2022). Design of structural elements: concrete, steelwork, masonry and timber designs to eurocodes. CRC Press.[Retrieved from : https://www.taylorfrancis.com/books/mono/10.1201/9781003208037/design-structural-elements-chanakya-arya][Retrieved on : 5/9/25]
  • Ellobody, E. (2023). Finite element analysis and design of steel and steel–concrete composite bridges. Elsevier.[Retrieved from : https://books.google.com/books?hl=en&lr=&id=6XqAEAAAQBAJ&oi=fnd&pg=PP1&dq=REINFORCED+CONCRETE+AND+STEEL+STRUCTURES+DESIGN&ots=1lynOhH02_&sig=ihkPq0TeMwqXYdpOb_U3jdtoaeE][Retrieved on : 5/9/25]
  • El-Reedy, M. A. (2023). Steel-reinforced concrete structures: Assessment and repair of corrosion. CRC press. [Retrieved from :https://www.taylorfrancis.com/books/mono/10.1201/9781003407058/steel-reinforced-concrete-structures-mohamed-abdallah-el-reedy ][Retrieved on : 5/9/25]
  • Gruyter, D. (2025). Structural steel design. Walter de Gruyter GmbH & Co KG.[Retrieved from : https://books.google.com/books?hl=en&lr=&id=rZxnEQAAQBAJ&oi=fnd&pg=PT16&dq=REINFORCED+CONCRETE+AND+STEEL+STRUCTURES+DESIGN&ots=jqCgtDj79B&sig=s7PpsCvDZvRMTuAjfxl5juaSOO8][Retrieved on : 5/9/25]
  • Hart, J., D'Amico, B., & Pomponi, F. (2021). Whole‐life embodied carbon in multistory buildings: Steel, concrete and timber structures. Journal of Industrial Ecology, 25(2), 403-418.[Retrieved from : https://onlinelibrary.wiley.com/doi/abs/10.1111/jiec.13139][Retrieved on : 5/9/25]
  • Huang, H., Yao, Y., Liang, C., & Ye, Y. (2022). Experimental study on cyclic performance of steel-hollow core partially encased composite spliced frame beam. Soil Dynamics and Earthquake Engineering, 163, 107499.[Retrieved from : https://www.sciencedirect.com/science/article/pii/S0267726122003475][Retrieved on : 5/9/25]
  • Ivanov, M. L., & Chow, W. K. (2023, December). Structural damage observed in reinforced concrete buildings in Adiyaman during the 2023 Turkiye Kahramanmaras Earthquakes. In Structures (Vol. 58, p. 105578). Elsevier.[Retrieved from : https://www.sciencedirect.com/science/article/pii/S2352012423016661][Retrieved on : 5/9/25]
  • Kazemi, F., Asgarkhani, N., & Jankowski, R. (2023). Machine learning-based seismic fragility and seismic vulnerability assessment of reinforced concrete structures. Soil Dynamics and Earthquake Engineering, 166, 107761.[Retrieved from :https://www.sciencedirect.com/science/article/pii/S0267726123000064 ][Retrieved on : 5/9/25]
  • Pan, W., & Zhang, Z. (2023). Benchmarking the sustainability of concrete and steel modular construction for buildings in urban development. Sustainable cities and society, 90, 104400.[Retrieved from : https://www.sciencedirect.com/science/article/pii/S2210670723000112][Retrieved on : 5/9/25]
  • Rabi, M., Shamass, R., & Cashell, K. A. (2022). Structural performance of stainless steel reinforced concrete members: A review. Construction and Building Materials, 325, 126673.[Retrieved from : https://www.sciencedirect.com/science/article/pii/S0950061822003646][Retrieved on : 5/9/25]
  • Sadkovyi, V., Andronov, V., Semkiv, O., Kovalov, A., Rybka, E., Otrosh, Y., ... & Kovalov, P. (2021). Fire resistance of reinforced concrete and steel structures. Fire Resistance of Reinforced Concrete and Steel Structures, Kharkiv: РС ТЕСHNOLOGY СЕNTЕR, 180.[Retrieved from :https://papers.ssrn.com/sol3/papers.cfm?abstract_id=4008013 ][Retrieved on : 5/9/25]
  • Selvaraj, S., & Chan, T. M. (2024). Recommendations for implementing circular economy in construction: direct reuse of steel structures. Journal of constructional steel research, 214, 108439.[Retrieved from : https://www.sciencedirect.com/science/article/pii/S0143974X23006661][Retrieved on : 5/9/25]
Recently Download Samples by Customers
Assignment Giving You Nightmares? Our experts are your Halloween heroes — save big today!

© Copyright 2026 | New Assignment Help | All rights reserved

DMCA Protected Website Badges
↑